Industrial Automation
OMRON Scientific Technologies, Inc.
Omron IAB global
Products
Safety Light Curtains
Perimeter Access Guarding
Safety Laser Scanners
Safety Mats
Programmable Safety Controllers
Safety Edges & Bumpers
Emergency Stop Devices
Safety Interlock Switches
Force-Guided Relays
Safety Systems & Safety Monitoring Relays
Power Relays with Mirror Contacts
Two-Hand Control
Enabling Switch Device
Process Safeguarding
Safeguarding for Cutting and Turning Machines
Disconnect Switches, Motor Starters and Accessories
Awareness Signs
Safeguard Integration Services
Industrial Automation Products
Expert Area
SISTEMA data
Instant Access to ANSI Standards
Engineering Topic
Standards
Articles & Information
Applications & Solutions
Safeguarding Integration Services
Contact Us
Services
Safeguarding Integration Services
Technical Support
Training
SISTEMA data
Instant Access to ANSI Standards
Terms & Conditions and Policies
Contact Us
Customer Care
Company Info
Contact Us
Omron Sti Careers
About Omron STI
About Omron Automation & Safety - Americas
About Omron
Environmental
Terms & Conditions and Policies
Search Catalog
By Keyword
By Item #
All Categories
EC Series Electrically Coded Interlock Switch and Control Unit
All Categories
>
Safety Interlock Switches
>
Safety Interlock Switches for Non-Contact Operation
>
EC Series Electrically Coded Interlock Switch and Control Unit
>
Item # 44537-0115
Printable Page
Email This Page
Save To Favorites
Please wait…
Item # 44537-0115, EC Series Electrically Coded Interlock Switch and Control Unit
larger image
>
The EC Series Control Units individually monitor one to four Read Heads to provide a Category 4 system for applications with up to four guard doors
Uniquely coded actuators provide a high level of tamper resistance
Misalignment of nearly 1/2 inch allows application on machine doors with a high level of vibration or alignment issues
Manual or automatic start is switch selectable
External Device Monitoring (EDM) allows the EC Series Control Unit to function as a safety monitoring relay
The 6 A/24 VDC switching capability of the Control Unit allows connection directly to power contactors
Individual guard door status may be monitored with the semiconductor outputs from the Control Unit; an additional output gives status of the Control Unit
Guarding applications with more than four doors may be achieved by combining two or more Control Units in series while continuing to satisfy Category 4 according to EN954-1
Approved for use in Class I, Div. 2 gas and dust applications
Description
The EC Series consists of a uniquely coded actuator, a read head (switch), and a control unit capable of monitoring 1 to 4 read heads.
The uniquely coded actuator is a device known as a transponder (transmitter and responder) while the read head is a device known as a transceiver (transmitter and receiver). The actuator (transponder) receives an electromagnetic field from the read head (transceiver), processes it and sends data signals back to the read head which are read by the control unit. The data signals received by the control unit must match the known data signals of the control unit in order to close the safety outputs of the control unit.
Each actuator has a uniquely coded element within the actuator that can not be reprogrammed which makes the actuators secure against manipulation. The ‘Teach-In Operation’ is used to ‘teach’ the control unit the code of each of the 1 to 4 actuators that are to be used with the read heads connected to the control unit. No additional equipment is required to perform the teach-in operation and there is no limit to the number of teach-in operations that may be performed.
The EC-S2 and EC-S4 control units provide EDM (External Device Monitoring, also called MPCE monitoring) and may be operated in manual or automatic start mode allowing the control unit to function as a safety monitoring relay. There are also 2 or 4 solid state outputs on the control unit for individual monitoring of the status of each read head plus an additional output for the monitoring of the status of the control unit.
The EC-S1 switch is available with a wide variety of cable lengths to 25 meters or with an integral connector to accommodate a variety of application requirements.
Specifications are subject to change without notice.
Note:
The safety contacts of the Omron STI switches are described as normally closed (N/C) i.e., with the guard closed, actuator in place, and the machine able to be started.
Specifications
·
Electrical
·
Mechanical
·
Environmental
·
Compliance
Specifications
Model
Switch (Read Heads) PVC Fixed Cable
Shipping requirements
Request Availability
Type
EC-S1PC15 Switch & Actuator
Electrical
Contacts
Transceiver
Wiring Entry
15 m cable
Mode of Operation
Inductive
Data Transfer to Control Unit
2
Kbit/s
N/C Operating Distance
On = 10 to 15 mm; Off = 32 mm (25 m cable)
Mechanical
Mounting
4 x M4 screws
Case Material
Glass-filled Fortron plastic
Max. Wire Size
Pre-wired PVC cable to 10 m (50 m max. cable length)
Weight
300
g
10.6
oz
Color
Red
Environmental
Protection
IP67 (NEMA 6)
Operating Temperature
-25 to 70
ºC
-13 to 158
ºF
Compliance
Standards
EN954-1, EN1088, EN60204-1
Approvals/Listings
CE marked for all applicable directives, UL, C-UL, BG, and TUV to ATEX 100a for Ex zone 2 and 22
Safety Category
Cat. 4 per EN954-1
DOWNLOADS
Data Sheets
Manual
Certifications
SISTEMA Data
Relays
SR101A Single-Channel Safety Monitoring Relay
SR104P Two-Hand Control Safety Monitoring Relay
more available ..
Accessories
EC - Accessories
Replacement Contact Blocks
more available ..
Back to Top
Safety Light Curtain
Perimeter Access Guarding
Safety Laser Scanner
Safety Mats
Safety Interlock Swithces
Safety Systems & Safety Monitoring Relays
Programmable Safety Controllers
Emergency Stop Devices
Safety Edges & Bumpers
Force-Guided Relays
Power Relays with Mirror Contacts
Two Hand Control
Enabling Switch Device
Process Safeguarding
Safety Integration Services
Industrial Automation Products
Omron Americas
Omron Corporation
Legal Notices
Privacy Policy
Copyright © OMRON Scientific Technologies, Inc. 2006-2013 All Rights Reserved