Item # 44510-1061, SR106ED Safety Expansion Unit





  • Power requirements-the SR106ED will accept 24 VAC/DC, 115 VAC or 230 VAC
  • Outputs-the SR106ED has 3 N/O delayed outputs to route power to the coils of power contactors (delay selectable from 1 to 30 sec.)
  • Auxiliary Output-the SR106ED has 1 N/C auxiliary for monitoring by the safety monitoring relay
  • PLC Compatible-The N/O off delayed output makes it possible to use the SR106ED on machines with Programmable Logic Controllers that require some time to execute an orderly shutdown.
Specifications are subject to change without notice.

Note: The safety contacts of the Omron STI switches are described as normally closed (N/C)-i.e., with the guard closed, actuator in place, and the machine able to be started.





Specifications  · Electrical  · Mechanical  · Environmental  · Compliance

Specifications

Model

SR106ED01

Shipping requirements

Normally in Stock US

Max. Wire Size

1 x 2.5 mm² (14 AWG) stranded

Outputs

3 N/O off delayed


Electrical

Power Supply ±10%, 50-60 Hz

24 VAC/DC

Auxiliary

1 N/C

Power Consumption

1 VA

Output Rating AC

Inductive AC-15, 4 A/230 V

Output Rating DC

Inductive DC-13, 2 A/24 V

Min. Switched Current/Voltage

20 mA/24 V

Impulse Withstand Voltage

2500 V

Max. Drop-Out Time

Equal to delay timer setting (75 ms by removing supply voltage)

Max. Output Fuse

6 A quick-acting or 4 A slow-acting


Mechanical

Mounting

35 mm (1.38 in.) DIN rail

Case Material

Fiber-filled Polyamide PA 6.6

Weight

230 g
8.1
oz

Color

Red

External Switches

Timer delay setting (1 to 30 sec.)

Indications

Green = K1 Closed
Green = K2 Closed

Mechanical Life

1 x 107 operations


Environmental

Enclosure Protection

IP20 terminals, IP40 (NEMA 1 housing)

Operating Temperature

-15 to 60 ºC
5 to 140
ºF

Humidity

93% RH at 40°C (104°F)


Compliance

Standards

EN 60204-1, EN 954-1, VDE 0113-1

Approvals/Listings

CE marked for all applicable directives, UL and C-UL, BG

Safety Category

Cat. 3 per EN954-1 (SR106 internal operation)