Item # A4E-B200HS, A4E - 3-position Enabling Switch, Two contacts, horizontal mounting, no rubber seal




3-position Enabling Switch
for Safer Robot Operation
  • Clicking feel
  • Conforms to U.S. standards (ANSI/RIA R15.06-1999) for 3-position switches
  • Can be mounted in two directions






  • Specifications  · Ratings  · Characteristics

    Specifications

    Shipping requirements

    Request Availability

    Standards

    UL Standard: UL508 (File No. E76675)
    TÜV SÜD Standard: EN60947 5-1 (certified direct opening), EN60947-5-8 (File No. Inquire)
    CQC (CCC) Standard: GB14048.5 (File No. 2003010305070634)

    Total Contact Number

    Two Contacts

    Enabling Outputs

    Two Contacts

    Release Monitor Outputs

    None

    Grip Monitor Outputs

    None

    Mounting Bracket

    Horizontal Mounting Bracket

    Cover

    No Cover


    Ratings

    Rated Insulation Voltage

    250 V

    Rated ON Current

    2.5 A

    Rated Load

    24 VDC, 300 mA (inductive load)
    125 VAC, 1 A (resistive load)

    Minimum Applicable Load

    24 VDC, 4 mA

    Impulse Withstand Voltage

    4.0 kV between terminals of different polarity, 2.5 kV between terminals of same polarity

    Ambient Operating Temperature

    -10 to 55 °C (with no icing)

    Ambient Operating Humidity

    35% to 85% (with no condensation)

    Ambient Storage Temperature

    -25 to 65 ºC


    Characteristics

    Insulation Resistance

    100 MΩ min. (at 500 VDC)

    Contact Resistance

    100 mΩ max. (initial value)

    Vibration Resistance

    10 to 55 Hz, 0.75-mm single amplitude min.

    Shock Resistance

    150 m²/s

    Mechanical Durability

    OFF-ON: 1,000,000 operations min.
    OFF-ON-OFF (direct opening): 100,000 operations min.

    Electrical Durability

    100,000 operations min.

    Degree of Protection

    IP65 (rubber seal type only)