Shipping requirements
|
|
Normally in Stock US
|
|
|
Max Wiring Size
|
|
14 AWG (1)
|
|
|
Housing Material
|
|
Nory lN190
|
|
|
Weight
|
|
313 g 11 oz
|
|
|
Actuation
|
|
Hand sensitive requiring no pressure to initiate, operates with or without gloves
|
|
|
Power Supply
|
|
120 VAC ±10%, 45 to 60 Hz
|
|
|
Power Consumption
|
|
≤ 1 W
|
|
|
Indicator
|
|
Red LED, illuminates when relays are energized
|
|
|
Outputs
|
|
Two relays provide 1 set of normally open contacts, 1 set of normally closed contacts. Force-guided contacts are used.
|
|
|
Contact Ratings
|
|
1 A at 250 VAC max resistive; 1 A at 90 VDC max resistive
|
|
|
Mechanical Life
|
|
Greater than 50 million operations
|
|
|
Electrical Life
|
|
Greater than 5 million operations at loads less than 50 VA
|
|
|
Mechanical Shock
|
|
45 g for 2 ms
|
|
|
Vibration
|
|
4 g at f ≤ 60 Hz and amplitude ≤ 1 mm
|
|
|
Relative Humidity
|
|
≤ 99%
|
|
|
Noise Protection1
|
|
Bursts to 2 kV, spikes of 500V, electrostatic fields to 8 kV
|
|
|
Weldfield Immunity2
|
|
Resistor welding up to 50 kA AC/DC (in suitable enclosure)
|
|
|
RFI
|
|
≤ 8 V/m
|
|
|
Protection
|
|
IP64
|
|
|
Temperature Range
|
|
-18 to 50 ºC 0 to 122 ºF
|
|
|
Max Response Times
|
|
On = 60 ms; Off = 80 ms
|
|
|
Approvals
|
|
CE marked for all applicable directives, UL and C-UL
|
|
1 If any of these values are exceeded, the TouchStart will default to a safe state (output relays de-energized). The
TouchStart automatically resets when conditions fall below the limit.
2 If any of these values are exceeded, the TouchStart will default to a safe state (output relays de-energized). The
TouchStart automatically resets when conditions fall below the limit.
|
|