OMRON Scientific Technologies, Inc.
6550 Dumbarton Circle
Fremont, CA 94555 USA
Toll Free: 888-510-4357   Tel: 510-608-3400   Fax: 510-744-1442
E-Mail: sales@sti.com    Web site: www.sti.com
All Categories > Safety Edges & Bumpers > Safety Edge Controllers > Safety Edge Controllers > Item # 43872-0021  


Item # 43872-0021, Single-Channel Safety Edge Din-Mount Controller for use with all safety edges, 120 VAC or 24 VDC;




Single and Dual-Channel
Safety Edge Controllers
for use with All Safety Edges and Safety Bumpers
  • Power requirements
    – 120 VAC or 24 VDC is acceptable for the SCC-1224 single channel units
  • Inputs
    – Single channel units accept a single two-wire edge or bumper system
  • Outputs
    – Single channel units have two safety outputs and one auxiliary output for signaling
  • External Device Monitoring –EDM is provided on all units with a N/C loop between Z1 and Z2
  • Monitored Reset Modes
    – Monitored manual reset mode that requires closure of the reset circuit followed by opening of the circuit is available on all units
    – Automatic reset mode that occurs upon closure of the reset circuit is available on all units
  • Delayed Auxiliary Output – Delayed opening of the auxiliary output for reversal of a door or gate may be selected on all units except SCC1224ND

Specifications are subject to change without notice

Auxiliary contact closes when the edge is activated and remains closed as long as the edge is activated






Specifications  · Performance  · Electrical  · Mechanical  · Environmental

Specifications

Model

SCC-1224ND

Shipping requirements

Normally in Stock Canada
Normally in Stock US


Performance

Category 3 Safety Device

Yes

Operating Area

Up to 5 sensing devices with a total cable length of max. 25 m in series

Response Time

< 13 ms

Indications

Green = Power – Main power supply
Orange = Aux. Actuate – Activate Aux. output

Red = Fault – Detect an irregular signal

Yellow = Actuate – Edge is depressed

Operational Modes (Selectable)

Automatic Start
Start/Restart Interlock


Electrical

Power Input

115 VAC, 50/60 Hz, 3 VA or 24 VAC/DC ± 10%, 1.5 W

Safety Outputs

2 N/O Relay

Maximum Switched Current (Safety Outputs)

4 A, 250 VAC / 4 A, 30 VDC

Auxiliary Relay Output

Activates if the sensing device is actuated or if a sensing device fault is detected

Maximum Switched Current (Auxiliary Relay Output)

4A, 250 VAC / 4A, 30 VDC

Terminal Blocks

Cage Clamp Terminal Strip, Wire Size 0.75-1.5 mm2

Input Connections

1-2 wire edge sensor circuit

Input Resistance

8.2 K ohm

Input Voltage

6 V ±2%

Input Current

1 mA


Mechanical

Enclosure

Polyamide PA6.6, Self-extinguishing in accordance with UL-94-V2

Mounting

35 mm DIN rail


Environmental

Protection Rating

IP20

Operating Temperature

-20 to 55 ºC
-4 to 131
ºF

Standards Conformity

CE, TUV

Designed to Meet or Exceed

Category 3, EN13849-1